Massivprim vault room

Vault room in massive construction – the classic solution for achieving a high level of safety.

Massive vault construction is a system of construction based on prefabricated safety reinforcement elements, which are installed on site between static reinforcements and poured with a concrete mix. The concrete is poured by a selected contractor, following precise instructions and under the supervision of Primat's experts.

Massivprim vault room
Our biggest project in 2014!
We have built a Massivprim vault room measuring 10.6 m x 54 m x 46 m (height, width, length). Total approx. 6800 m².
European standards and different safety levels
Massivprim vault rooms comply with the high European standard EN 1143-1 and the Slovenian standard SIST EN 1143-1, which define burglar-resistant security levels based on burglar-resistance grades. The Massivprim system is available in different security levels, so you can choose the optimal solution for your needs.
Certified quality
The Massivprim system has been tested by the Verband der Schadenversicherer (VdS) Cologne (Germany) accredited testing laboratory and has received all relevant certificates. The VdS label on the products confirms that they are of high quality, have been properly tested, and that production is controlled.

List of Massivprim vault room models

Model Resistance grade Wall thickness [mm]
MASSIVPRIM 5 V / 270 RU 400
MASSIVPRIM 6 VI / 400 RU 400
MASSIVPRIM 7 VII / 600 RU 400
MASSIVPRIM 8 VIII / 825 RU 400
MASSIVPRIM 9 IX / 1050 RU 400
MASSIVPRIM 9 CD IX CD / 10000 RU 400
MASSIVPRIM 10 X / 1350 RU 500
MASSIVPRIM 10 CD X CD / 10000 RU 500
MASSIVPRIM 11 XI / 2000 RU 600
MASSIVPRIM 11 CD XI CD / 10000 RU 600
MASSIVPRIM 12 XII / 3000 RU 750
MASSIVPRIM 12 CD XII CD / 10000 RU 750
MASSIVPRIM 13 XIII / 4500 RU 1000
MASSIVPRIM 13 CD XIII CD / 10000 RU 1000
The minimum internal dimensions of the vault room are:
Minimum height = 2300 mm
Minimum width = 2000 mm
Minimum depth = 2000 mm

Construction of Massivprim vault rooms

In the construction of Massivprim vault rooms, Primat d.d. supplies and installs security fittings and vault doors, prepares installations for the alarm system, cable entries and ventilation elements.

The installation of the static reinforcement, the formwork of the vault room and the pouring of concrete is carried out by a selected construction contractor.

Course of construction

Construction is carried out in new buildings and adaptations of existing buildings in basements or on lower floors, if the building has no basement. The Massivprim safety reinforcement elements are welded together, formworked and poured with high strength concrete to integrate them into the building. The construction is permanent and cannot be relocated at a later date. The installation time of the safety reinforcement elements is significantly shorter than that of the static reinforcement and all other construction works, so that the Massivprim system does not have a significant impact on the extension of the construction time of buildings.

We can provide a vault room with wall and floor linings, lighting and additional installations as an additional service.

The cable entries are designed for 51 mm diameter cable ducts.
You can choose between ventilation elements for natural or forced ventilation.
Doorprim vault doors are installed in a pre-prepared opening in the vault wall.
Preparation for the installation of the elements of an EMA burglar alarm system for automatic burglar protection.

Interior

The interior design of the vault room is tailored to the customer's requirements and wishes. We offer:

We would be pleased to advise you on your choice.

Construction of a Massivprim vault room in pictures

Installation of floor safety reinforcement.
Installation of floor safety reinforcement.
Installation of safety and static reinforcement is carried out simultaneously.
Installation of safety and static reinforcement is carried out simultaneously.
Installation and assembly of wall safety reinforcements.
Installation and assembly of wall safety reinforcements.
Safety and static reinforcement of the vault room, ready for formwork and then pouring with premixed concrete.
Safety and static reinforcement of the vault room, ready for formwork and then pouring with premixed concrete.
Vault room after pouring of concrete.
Vault room after pouring of concrete and removal of framework.
Installation and assembly of vault doors.
Installation and assembly of vault doors.
contact